5D SERIES MINIATURE PUMP
OPERATION and MAINTENANCE
INSTRUCTION MANUAL
Contents:
General Information, Installation...........1
Operation, Wiring, and
Maintenance Inspection........................2
Exploded View and Parts Ordering
Information............................................3
Troubleshooting, and
Service Facilities...................................4
70-2500 G446BPL (Rev. C)
This is the hazard alert symbol: m When you see
this symbol be aware that personal injury or
property damage is possible. The hazard is
explained in the text following the symbol.
Read the information carefully before proceeding.
The following is an explaination of the three dif-
ferent types of hazards:
mDANGER Severe personal injury or death
will occur if hazard is ignored.
mWARNING Severe personal injury or death
can occur if hazard is ignored.
mCAUTION Minor injury or property damage
can occur if hazard is ignored.
GENERAL INFORMATION
mDANGER To prevent explosive hazard, do not
pump combustible liquids or
gases, or operate the pump in an
atmosphere containing them. Use
only in a well ventilated area.
m CAUTION Required ambient temperature is
-10 F to 150 F. For operation at
temperatures outside this range,
consult the factory.
Performance is reduced by lower atmospheric
pressure at high altitudes. Consult a Gast dis-
tributor for details. Never lubricate this oil-less
pump. The sealed bearings are grease-packed.
The service life of the diaphragm and valve will be
reduced by petroleum or hydrocarbon products.
INSTALLATION
mWARNING Beware of any exposed movable
parts. Proper guards should be in
place to prevent severe personal
injury.
mCAUTION Do not block the flow of cooling air
over the pump in any way.
MOUNTING
To reduce noise and vibration use shock mounts
or a vibration-isolated mounting surface. Do not
block the flow of cooling air over the unit in any
way.
PLUMBING
To prevent air flow restriction, use pipes and
fittings of the same size or larger than the barbed
ports. Note that the ports are not designed to
support plumbing.
KEEP THIS DOCUMENT FOR FUTURE REFERENCE
Vedere la pagina 0
1 2 3 4

Sommario

Pagina 1 - INSTRUCTION MANUAL

5D SERIES MINIATURE PUMPOPERATION and MAINTENANCEINSTRUCTION MANUALContents:General Information, Installation...1Operation, Wiring, andMainten

Pagina 2

RELIEF VALVES AND GAUGESInstall gauges in the lines to monitor per-formance. A relief valve can be installed at theinlet or outlet, or both. Consult

Pagina 3 - DC WIRING

MAINTENANCE conti.-Place the valve in the valve plate pocket so thatthe holes in the valve fit over the correct pins inthe valve plate.-Assemble the h

Pagina 4 - TROUBLESHOOTING GUIDE

SYMPTOM POSSIBLE CAUSE POINT TO CHECK REMEDYWon’t Start•Electrical Connection•Dirty Muffler•Wrong/Low Voltage•Pressure/Vacuum onHead•Ensure electrical